Interlink Electronics logo
OS-6 Ozone Controller

Gas Sensing

OS-6 Ozone Controller

$1,195.00

Back to products

Product details

OS-6 Industrial Grade Ozone Controller and Monitor

The OS-6 is an industrial grade ozone controller and monitor. The OS-6 design has been optimized for accuracy, ease of installation, setup and operation. Multiple sensor options are available with the OS-6:

  • SM-500/RME 0-20 ppm: ACTIVE – IN STOCK:
    • Smaller form-factor electrochemical-based sensor module with re-zero button, T/RH compensation, and reduced VOC sensitivity. MORE INFO
  • SM-500/RME 1-50 ppm: ACTIVE – IN STOCK:
    • Smaller form-factor electrochemical-based sensor module with re-zero button, T/RH compensation, and reduced VOC sensitivity. MORE INFO
  • SM-7/SM-EC 0-20 ppm: END OF LIFE – NO STOCK REMAINING
  • SM-7/SM-EC 1-50 ppm: END OF LIFE – LIMITED STOCK AVAILABLE:
    • 1-50 PPM. Legacy electrochemical-based sensor module with T/RH compensation and reduced VOC sensitivity. Available calibration range: 1-50 ppm – MORE INFO

Features:

  • Industrial strength, water resistant enclosure.
  • Large digital display, auto-ranging (0-50ppm) w/ backlight.
  • Easy front panel access to set points and relays.
  • Precisely adjustable max, min, and fail time set points.
  • Failure alarm if ozone remains outside control range.
  • Front panel generator control cutoff switch for easy maintenance.
  • User selectable PPM ranges for analog output (4-20 mA and 0-2 VDC)
  • OSHA 0.1 ppm safety limit light.

Specifications:

  • Enclosure: Wall mounted polycarbonate enclosure resists water spray and splash (NEMA 4X).
  • Size:  H = 6.3”/160mm, W = 6.5”/166mm, D = 4.6”/118mm.
  • Power in:  12-24 VDC.
  • Power out:  +5 or +12-24 VDC to sensor.
  • Data in:  RS-232 serial data from remote sensor module (SM-4 or equivalent).
  • Data out:  RS-232, 9600 Baud 8N1 format.
  • Analog out:  0-2 V and 4-20 mA, internal jumpers select full scale PPM range.
  • Control in:  Generator enable (contact closure).
  • Control outputs:  Relays, 10A @ 25VDC, 0.25A @ 250VDC, 2.0 KVA AC (resistor).
  • Relay functions:  Ozone generator control, >100 PPB safety limit, failure to control.
  • User controls (internal):  MAX set point, MIN set point, FAIL time, increase, decrease.
  • Numeric display:  Four digits, 0.5”/12mm, auto-ranging, with backlight.
  • LED indicators:  Sensor, above MAX, below MIN, >100 PPB, generator on, failure

Product manual PDF file (1Mb) (requires Adobe Acrobat ™ reader)

Instructions for viewing and capturing data output: RS-232 Communications Manual

Technical Documentation

Product downloads

Datasheets, manuals, CAD files, application notes, and related technical resources for this product category.

Category Overview

Gas Sensing Ecosystem

Interlink supports gas sensing from raw electrochemical elements through finished monitors, analyzers, and connected wearable products.

The gas portfolio covers OEM sensor elements, analog and digital modules, ozone and air-quality instrumentation, fixed and portable analyzers, and connected personal monitoring products for field and consumer use.

These products fit industrial safety, indoor air quality, smart-environment deployments, commercial monitoring, and application-specific gas detection workflows where sensor accuracy and deployment context both matter.

On the main Interlink site, gas products are presented as one category so buyers can evaluate the broader product range without switching brands or visual systems mid-journey.

  • Electrochemical elements, modules, monitors, analyzers, and wearables
  • Supports OEM integration, finished-product deployment, and technical evaluation
  • Fits industrial, environmental, medical, and consumer monitoring workflows
  • Unified Interlink category messaging with product-specific technical follow-up

As Seen In

Company coverage and market visibility

Contact SalesRequest Quote
OS-6 Ozone Controller | Interlink Electronics